http://https://www.newpassleader.com/Dell/DCPPE-200-exam-preparation-materials.html (88 Q&As Dumps, 30%OFF Special Discount: 30free )
NEW QUESTION NO: 8
A customer has five VRTXs in a chassis group that they need to disband. The engineer disbands the chassis group from the group leader, but a networking interruption prevents two of the VRTXs from getting the signal to leave the group.
What should the engineer do to finish disbanding the chassis group?
A. Remove the group association from the group members individually
B. Reboot the CMCs of the remaining members
C. Recreate the group from the group leader and disband it again
D. Remove the remaining members from the group leader's Remove Members list
Answer: A
NEW QUESTION NO: 9
An engineer configures an Alert Action in the CMC to send an email on Warning and Critical events.
Chassis fan and power events are showing up as expected. Server-specific failures such as memory module failures only indicate that the server has gone into a Critical or Warning state.
What additional configuration needs to be done to be informed via email of the detailed server failure?
A. Enable Forward iDRAC events to CMC error log in iDRAC.
B. Select Server Event under Monitored Alerts Category in CMC.
C. Email Alert Action for Critical and Warning errors on all iDRACs.
D. Set Include System Event Log (SEL) option in CMC email action.
Answer: D
NEW QUESTION NO: 10
An engineer is redeploying an PS-M4110 storage array in an M1000e chassis. The engineer chooses Configure Array from the CMC. All settings are unavailable.
What should the engineer do to allow the CMC to configure the array?
A. Run resetfrom a serial connection to the array
B. SSH to the CMC and run racadm sanresetcfg
C. Add Storage Configuration to the user account for the CMC
D. Choose Reset from the iDRAC of the storage array
Answer: C
NEW QUESTION NO: 11
In VRTX the following features are enabled:
1. Server Module Firmware Update
2. Remote syslog
3. iDRAC Single Sign-on.
4. Server configuration
5. Chassis grouping
6. Enclosure level backup
Which license type is required?
A. CMC enterprise license
B. CMC express license
C. iDRAC express license
D. iDRAC enterprise license
Answer: A
Explanation/Reference:
Reference: http://en.community.dell.com/cfs-file/__key/telligent-evolution-components-attachments/13-
4491-00-00-20-40-24-15/VRTX-CMC_5F00_Feature-Guide.pdf?forcedownload=true
NEW QUESTION NO: 12
An engineer is migrating an existing server node from an M1000E to a VRTX chassis. An error message appears during POST. The system will continue to boot, but can NOT see any of the chassis shared storage or PCIe devices mapped to the server slot. The engineer has already removed the original fabric interfaces in mezzanine slot B and C from the original system configuration.
Which action must the engineer complete to allow the node to see chassis storage and mapped PCIe devices?
A. Update the CPLD firmware version
B. Enable PCIe Pass-Through in System Setup
C. Install PCIe Pass-Through mezzanine cards
D. Remap chassis storage/PCIe devices
Answer: B
NEW QUESTION NO: 13
An engineer needs to connect ports 49 and 53 on an MXL to a top of rack (ToR) switch in an LACP port channel. The ToR switch has ports 46 and 60 configured in port channel 100.
Which configuration will successfully bring up the port channel on the MXL?
A. interface Port-channel 1
switchport
interface range fortyGigE 0/46, fortyGigE 0/60
port-channel-protocol LACP
port-channel 1 mode active
B. interface Port-channel 100
channel member fortyGigE 0/49, firtyGigE 0/53
switchport
interface range fortyGigE 0/49, fortyGigE 0/53
port-channel 100 mode active
C. interface Port-channel 100
channel member fortyGigE 0/49, fortyGigE 0/53
switchport
interface range fortyGigE 0/49, fortyGigE 0/60
lacp mode active
D. interface Port-channel 1
switchport
interface range fortyGigE 0/49, fortyGigE 0/53
port-channel-protocol LACP
port-channel 1 mode active
Answer: C
NEW QUESTION NO: 14
An engineer is in front of an FX2 chassis and notices the I/O indicator on the left ear of the chassis is flashing amber.
What are two possible causes? (Choose two.)
A. A network link has failed for one of the add-in PCIe NICs.
B. A hard drive in one of the storage sleds has failed.
C. A USB key plugged into the front of the chassis has failed.
D. There is a problem with the chassis PCIe infrastructure.
Answer: B,D
NEW QUESTION NO: 15
A VRTX server is being set up for a new customer and configured with four blades. After a shutdown from a power outage, blades do NOT power up automatically upon power restore. Blades can be powered up either manually or via CMC.
Which setting should be verified to make sure blades automatically power up upon power restore?
A. Verify Power Control Operations in the CMC GUI under Chassis Power Control
B. Verify chassis status with command racadm autopowerup -m
C. Verify Power Configuration in the Lifecycle Controller GUI iDRAC Settings
D. Verify AC Power Recovery settings in the BIOS for each blade
Answer: A
Explanation/Reference:
Reference: https://community.spiceworks.com/topic/505996-dell-vrtx-box-does-not-power-on-after-power- restored
NEW QUESTION NO: 16
An engineer is deploying a chassis with four IOAs and connecting it to the top of rack (ToR) switch. The deployment mandate requires that the switches be presented as one logical unit. Future servers can be added to network with the minimal amount of configuration.
The following steps have been completed:
- IOAs are daisy-chained using ports 9 and 10
- Cabled ports 11 and 12 on IOA 1 to the ToR
- Configured a team on NIC ports 1 and 2 on the server
How should the IOMs be configured?
A. Full Switch
B. Stack
C. Programmable MUX
D. Virtual Link Trunking
Answer: C
NEW QUESTION NO: 17
An engineer needs to configure a full height blade server and iSCSI traffic. The blade has two dual port NDCs. The M1000e chassis only has switches in A fabric.
A1 - Production traffic:
174.1.0.0/16 network
Server facing switch ports use tagged VLANs 10, 30, 50
A2 - iSCSI traffic:
10.0.0.0/24 network
Untagged traffic
Switch is set to access VLAN 20
The engineer needs to set up the host to operate on the iSCSI network using two ports.
Which ports should be used?
A. Use NIC port 2 and 4 together for iSCSI
B. Use NIC port 1 and 4 together for iSCSI
C. Use NIC port 3 and 4 together for iSCSI
D. Use NIC port 1 and 3 together for iSCSI
Answer: A
NEW QUESTION NO: 18
A password to the CMC root account on an M1000e server chassis has been misplaced.
What should be done to restore administrative access to the CMC?
A. Reset root password using the PASSWORD_RSET jumper
B. Issue password reset from a connected blade's iDRAC
C. Call Dell tech support and ask to reset CMC password via SupportAssist
D. Access CMC through serial console and issue the enable secretcommand
Answer: A
Explanation/Reference:
Reference: http://www.dell.com/support/manuals/us/en/19/dell-cmc-v5.10-m1000e/CMCM1000e51UG-v1/ Resetting-Administrator-Password?guid=GUID-22C032BF-4A40-4F6D-8CA9-AC5E073ECCE6&lang=en- us